THYRISTORS
INSEL Rectifiers India Thyristors may also be necessary to act in the opening switch mode as well. Such applications may contain those where voltage is reapplied to the pulse power switch shortly after closing and the switch needs to have improved blocking capability or the transfer energy needs to be controlled. In these applications, the switch needs to have turn-off capability to decrease the natural turn-off time (tq) of the device. The device is operated in GTO mode with the suitable commutating gate drive.
Thyristors may be used to bond a source of stored energy, such as a capacitor to a load, or to bypass and protect the load in the case of a crowbar circuit. In these pulsed power applications where the rate of rise of current is very fast, the pulse power switch is acting as a closing switch and ordinary phase control thyristors (SCRS) are probable to fail due to the high di/dt experienced?
Thyristors or SCRs (silicon controlled rectifiers). The Phase Control SCR provides phase-control of ac signals with a line frequency of 50-60 Hz. The Inverter SCR is used in pulsed power applications connecting higher frequencies. The main difference between the two families is the turn-off time (tq). Inverter SCRs typically have a tq of less than 30 microseconds (µs). Similar phase control SCRs has tq ratings of several hundred µs.
Thyristors or SCRs (silicon controlled rectifiers).
Applications:
- UPS
- Welding
- Power Supplies
- VAR Generators
- Transportation
- Traction Inverter
- Medium Voltage Inverter
- Flexible AC Transmission
- Medical
- Motor control
- Battery Chargers
- UPS Systems
- Induction Heating
Call Us For Any Of Your Query
adipiscing elit, sed do eiusmod tempor
incididunt ut labore et dolore
Our Catalogue
PlateType | Mechstructure | Fig.Ref. | Width(W)mm | Height(W)mm | F.L(Cx2) +PXN | Pitch(P)mm | SpindleDia(D) | EProjections on both sides mm |
C D E F G K M Q R Y S N T P | L L LA L L L LA L LA L LA L LA L LA L LA L LA L LA L LA L LA L | 6 6 6 4 6 2 2 4 4 2 2 5 5 5 5 5 5 2 2 4 4 5 5 1 1 | 17 23 23 36 36 50 50 50 50 76 76 62 62 76 76 83 83 100 100 152 152 100 100 381 381 | 32 35 35 35 48 68 68 100 100 100 100 122 122 122 122 122 122 122 122 100 100 185 185 100 10 | 32+PxN 32+PxN 32+PxN 32+PxN 32+PxN 20+PxN 20+PxN 20+PxN 20+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 45+PxN 51+PxN 51+PxN | 2.5 3. 35 5.8 5.8 7.1 7.0 8.5 7.0 8.5 9.9 12.2 12.2 17.3 9.9 12.2 9.9 12.2 12.2 17.3 12.2 17.3 12.2 17.3 9.9 12.2 | 3/16 316 316 316 316 1/4 1/4 1/4 1/4 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 | 10 10 10 10 10 15 15 15 15 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 |
Device | VRRM | IF(AV) | TC | VFM | IFSM | I2t | IRRM | Rth(j-c) | Mounting | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Type | IF(AV) | @ I peak | Torque | Heat Sink Rec. | Thread | Package | Outline | ||||||
(V) | |||||||||||||
(V) | (A) | (0C) | (A) | A2Sx103 | (mA) | (0C/W) | (Nm) | ||||||
12NA/RA | 400-1800 | 12 | 160 | 1.3 | 265 | 0.351 | 2 | 2 | 2 | K1 | M-6 | DO-4 | A |
16NA/RA | 400-1800 | 16 | 160 | 1.2 | 350 | 0.612 | 4 | 1.6 | 2 | K1 | M-6 | DO-4 | A |
25NA/RA | 400-1800 | 25 | 140 | 1.35 | 400 | 0.8 | 4 | 1.5 | 2 | K1 | M-5, M-6 | DO-4 | A |
25NB/RB | 400-1800 | 25 | 140 | 1.35 | 400 | 0.8 | 4 | 1.5 | 2 | K2, K3 | M-6.M-8,1/4" | DO-5 | B |
40NB/RB | 400-1800 | 40 | 140 | 1.35 | 500 | 1.25 | 10 | 1 | 4 | K2, K3 | M-6,M-8, 1/4" | DO-5 | B |
PAO40A/PAO40C | 800-1800 | 40 | 140 | 1.35 | 500 | 1.25 | 10 | 1 | 4 | RRA | M-8 | DO-5 | B |
70NC/RC | 400-1800 | 70 | 140 | 1.35 | 1200 | 7.1 | 10 | 0.45 | 4 | K3, K4 | M-6,M-8 | DO-5 | C |
100NE/RE (Flat Base) | 400-1800 | 100 | 130 | 1.5 | 2300 | 24 | 15 | 0.4 | 10 | K4, K5 | Flat Base | DO-8 | E |
100ND/RD | 400-1800 | 100 | 130 | 1.5 | 2300 | 24 | 15 | 0.4 | 10 | K4, K5 | M-16 | DO-8 | D |
150ND/RD | 400-1800 | 150 | 130 | 1.4 | 3570 | 64 | 22 | 0.25 | 10 | K4, K5 | M-16 | DO-8 | D |
200NE/RE (Flat Base) | 400-1800 | 200 | 130 | 1.35 | 3650 | 66.6 | 22 | 0.25 | 10 | K4, K5 | Flat Base | DO-8 | E |
200ND/RD | 400-1800 | 200 | 130 | 1.35 | 3650 | 66.6 | 22 | 0.25 | 10 | K4, K5 | M-16 | DO-8 | D |
250NF/RF (Flat Base) | 400-1800 | 250 | 130 | 1.35 | 4500 | 92.5 | 40 | 0.18 | 30 | K5 | Flat Base | DO-9 | F,G |
250NG/RG | 400-1800 | 250 | 130 | 1.35 | 4500 | 92.5 | 40 | 0.18 | 30 | K5 | M-20 | DO-9 | F,G |
300NF/RF (Flat Base) | 400-1800 | 300 | 130 | 1.4 | 5000 | 125 | 50 | 0.12 | 30 | K5 | Flat Base | DO-9 | F,G |
300NG/RG | 400-1800 | 300 | 130 | 1.4 | 5000 | 125 | 50 | 0.12 | 30 | K5 | M-20 | DO-9 | F,G |
320NF/RF (Flat Base) | 400-1800 | 320 | 130 | 1.65 | 5500 | 151 | 50 | 0.12 | 30 | K5 | Flat Base | DO-9 | F,G |
320NG/RG | 400-1800 | 320 | 130 | 1.65 | 5500 | 151 | 50 | 0.12 | 30 | K5 | M-20 | DO-9 | F,G |
350NF/RF (Flat Base) | 400-1800 | 350 | 125 | 1.2 | 6000 | 180 | 50 | 0.12 | 30 | K5 | Flat Base | DO-9 | F,G |
350NG/RG | 400-1800 | 350 | 125 | 1.2 | 6000 | 180 | 50 | 0.12 | 30 | K5 | M-20 | DO-9 | F,G |
400NG/RG | 400-1800 | 400 | 120 | 1.62 * | 8250 | 340 | 50 | 0.12 | 50 | K5 | M-20 | DO-9 | F,G |
400NF/RF (Flat Base) | 400-1800 | 400 | 120 | 1.62 * | 8250 | 340 | 50 | 0.12 | 50 | K5 | Flat Base | DO-9 | F,G |
410NJ/RJ (Stud) | 400-1800 | 400 | 120 | 1.62* | 8250 | 340 | 50 | 0.12 | 50 | K5 | M-20, M-24 | D0-9 | J |
410NU/RU (60x60 Base) | 1200-3600 | 410 | 120 | 1.15 * | 7000 | 245 | 50 | 0.15 | 15 /Bolt | ED, K5 | Flat Base | U | U |
570NU/RU (60 x 60 Base) | 1200-4300 | 570 | 80 | 1.65 * | 12000 | 725 | 50 | 0.065 | 15 /Bolt | ED | Flat Base | U | U |
860NU/RU (60 x 60 Base) | 1200-1800 | 860 | 80 | 1.65 * | 16000 | 725 | 50 | 0.065 | 15 /Bolt | ED | Flat Base | U | U |
40029131 (Stud/Ceramic) | 2300-2800 | 280 | 100 | 1.30 * | 6500 | 125 | 50 | 0.13 | 30 | K5 | 3/4 UNF | DO-9 | H |
400NFC/RFC (Ceramic Flat) | 400-1800 | 400 | 120 | 1.62 * | 8250 | 340 | 50 | 0.12 | 50 | ED | FLAT | DO-9 | F |
40029132 (Stud/Ceramic) | 2300-2800 | 280 | 100 | 1.30 * | 6500 | 125 | 50 | 0.1 | 30 | K5 | 3/4 UNF | DO-9 | H |